Dose Dosage Straight Fiber Chopped Strands Fiber For Concrete Crimp Specific Gravity Steel Fiber
Technical requirements for ground construction of steel fiber reinforced concrete industrial buildings
General engineering mix
Steel fiber content (%) | sand ratio (%) | water cement ratio
| Collapsbillity (cm) | dosage per unit (Kg/cubic) | ||||
steel fibre | concrete | gravel | sand | water | ||||
1-1.2 | 40 | 0.45 | 3-5 | 78 | 450 | 1233 | 819 | 180 |
Crucial engineering mix
Steel fiber content (%) | sand ratio (%) | water cement ratio
| Collapsbillity (cm) | dosage per unit (Kg/cubic) | ||||
steel fibre | concrete | gravel | sand | water | ||||
1.5-1.8 | 46 | 0.45 | 3-5 | 120 | 450 | 1210 | 1035 | 200 |